Contact Us

Factory Cheap Hot Time Relay - Relay hw-RST 25 Phase Failure Under Overvoltage Sequence Relay – Hawai

Factory Cheap Hot Time Relay - Relay hw-RST 25 Phase Failure Under Overvoltage Sequence Relay – Hawai

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We emphasize enhancement and introduce new solutions into the market just about every year for Black Mini Circuit Breaker , Time Lag Relay , 6ka Circuit Breaker , We are hunting ahead to building positive and beneficial links with the businesses round the globe. We warmly welcome you to definitely call us to begin discussions on how we can easily bring this into being.
Factory Cheap Hot Time Relay - Relay hw-RST 25 Phase Failure Under Overvoltage Sequence Relay – Hawai Detail:

Connection

The RST 25 can be connected as following in the installation diagram:
FlG1: Connection of the relay before operation.
When the relay is connected as in FIG 1, the three yellow LED’s L1,L2 and L3 light up when the power supply A1 phase L, the A2 Neutral, and the three phases”L1,”L2″and”L3″are properly connected.
If there is no under of overvoltage, phase failure of phase sequence, the green LED lights up,(terminals 11 and 14 are closed ) and the relay is ready for operation.
FIG2: Connection of the relay after operation.
When the relay is connected as in FIG 2,(the power supply Al phase L, the A2 Neutral are properly connected) after operation, the three phases”L1″,”L2″and”L3″are connected, andthere is no under of overvoltage, phase falure, phase sequence, the green LED lights up(terminals 11 and
14are closed) and the relay is ready for self retaining.
It is also possible to connect the power supply after operation in FIG2.
By both FIG’s 1 and 2, the terminal “PE”must be grounded.

Undervoltage
The desired undervoltage limit can be adjusted down to -25% UN.

Overvoltage
The desired overvoltage limit can be adjusted up to +25% UN.

Asymmetry
When adjusting over-and undervoltage limit, the asymmetric limit is also adjusted.

Time Delay
The switch off time can be adjusted by the potentiometer “Time’ Delay”from 0.1….5 seconds. With this function it is possible to adjust the time for the identification of the failure.

Contactor Control
If a phase fails during operation at load or one of the contacts of the contactor or circuit breaker is defect,(contact bounce or scorched contacts), RST 25 recognizes the failure, and also the feedback voltage, and switches off depending on the setting of “Time Delay”
The RST 25 controls the phase shift. If there is a phase failure during operation the angle from the feedback voltage is 30° and the RST 25 recognizes this failure.


Product detail pictures:

Factory Cheap Hot Time Relay - Relay hw-RST 25 Phase Failure Under Overvoltage Sequence Relay – Hawai detail pictures


Related Product Guide:

We've been committed to offering easy,time-saving and money-saving one-stop purchasing support of consumer for Factory Cheap Hot Time Relay - Relay hw-RST 25 Phase Failure Under Overvoltage Sequence Relay – Hawai , The product will supply to all over the world, such as: Zurich, Egypt, Kuwait, During the development, our company has built a well-known brand. It is well highly acclaimed by our customers. OEM and ODM are accepted. We are looking forward to customers from all over the world to join us to a wild cooperation.
  • Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Christopher Mabey from Botswana - 2017.09.29 11:19
    The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Sally from Portugal - 2017.09.30 16:36
    Write your message here and send it to us