We stay with the basic principle of "quality initially, services first, steady improvement and innovation to fulfill the customers" for your management and "zero defect, zero complaints" as the quality objective. To perfect our company, we give the goods while using the good high-quality at the reasonable selling price for Auto Recloser , Ac Fuse , Vacuum Pumps , Your inquiry might be extremely welcomed plus a win-win prosperous development are what we've been expecting.
High Quality SPD - SPD 40KA lightning arrester surge protection device – Hawai Detail:

Model

Protection zone

Protection level

Suitable location

TU2-10
TU2-20

LPZ1,LPZ2 zone boundaries of and LPZn
zone

 Class 3

Normally installed in the distribution box of the premises; or installed in the computer information equipment, electronic equipment and control equipment, or the nearest lighting box, socket box.

TU2-40
TU2-60

boundaries of LPZ0B and LPZ1 zone,or LPZ1 and LPZ2 zone

 Class2

Usually installed in the building distribution electric box,metering box;or installed in the computer center,motor housing,building control room,monitoring room, industrial automation,operation room and other places of power distribution box;also can be installed in the general distributionbox of the six floors below building, or the general distribution box of villa

TU2-80
TU2-100

LPZOA,LPZ0B zone boundaries of LPZ1 zone

 Class1

Usually installed in the piercing
lined low voltage main distribution
cabinet

TU2-1

Used in LPZ0A,LPZ0B zone

 Class 1

Usually used in lightning riskhigher equipment system of the first primary surge protection, installed in the general distribution box of distribution box, outdoor distribution box and so on.

Distribution network grounding systemvoltage

Grounding system

TT system

TN-S system

TN-C-Ssystem

IT system

The maximum voltage of the grid

345V/360V

253V/264V

253V/264V

398V/415V

Main technical parameters and performance

Project Name

Parameter

TU2-10

TU2-20

Nominal discharge current

 In(kA)

   5

   10

Maximum discharge current

 Imax(KA)

10

20

Maximum continuous operating voltage

 Uc(V)

 275

320

 385

 275

320

 385

Voltage protection level

 Up(kV)

 1.0

1.3

1.3

 1.3

1.5

1.5

Test classification

   Grade III testing

   Grade III testing

Poles

   2,4,1N

   2,4,1N

Structure type

   D,B type

    D,B type

operation status

 Window indicator

Colorless or green:normal,red: fault

Colorless or green:normal,red: fault

Backup protective
appliances(suggestion)

 Backup fuse

   gl/gG16A

     gl/gG16A

 Backup CB

   C10

   C16

 dimensions

   Refer to drawing no.1,3,4

    Refer to drawing no.1,3,4

 

Project Name

Parameter

TU2-10

TU2-20

Nominal discharge current

 In(kA)

 20

30

Maximum discharge current

 Imax(KA)

40

60

Maximum continuous operating voltage

 Uc(V)

 275

320

 385

420

 275

320

 385

420

Voltage protection level

 Up(kV)

 1.5

1.5

1.8

2.0

 1.8

2.0

2.2

2.2

Test classification

   Grade III testing

   Grade III testing

Poles

   1,2,3,4,1N,3N

 1,2,3,4,1N,3N

Structure type

   D,B,X type

    D,B,X type

operation status

 Window indicator

Colorless or green:normal,red: fault

Colorless or green:normal,red: fault

Backup protective
appliances(suggestion)

 Backup fuse

   gl/gG40A

     gl/gG60A

 Backup CB

   C32

   C50

 dimensions

   Refer to drawing no.1,3,4

    Refer to drawing no.1,3,4


Product detail pictures:

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures


Related Product Guide:

While using the "Client-Oriented" organization philosophy, a rigorous top quality command process, highly developed production devices and a potent R&D workforce, we normally provide high quality products, outstanding solutions and aggressive charges for High Quality SPD - SPD 40KA lightning arrester surge protection device – Hawai , The product will supply to all over the world, such as: Greek, Albania, Mauritius, Now, with the development of internet, and the trend of internationalization, we've got decided to extend business to overseas market. With the propose of bringing more profits to oversea customers by providing directly abroad. So we have changed our mind, from home to abroad, hope to give our customers more profit, and looking forward to more chance to make business.
  • This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Henry from Durban - 2017.08.16 13:39
    High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
    5 Stars By Dinah from Uzbekistan - 2017.02.28 14:19
    Write your message here and send it to us