High Quality SPD - SPD 40KA lightning arrester surge protection device – Hawai

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our company since its inception, constantly regards product or service high quality as business life, continually improve creation technology, make improvements to product high-quality and consistently strengthen business total high-quality management, in strict accordance together with the national standard ISO 9001:2000 for Overload protect switch , Thermal Fuse , Bell , Living by good quality, enhancement by credit history is our eternal pursuit, We firmly feel that soon after your visit we will become long-term associates.
High Quality SPD - SPD 40KA lightning arrester surge protection device – Hawai Detail:

Model

Protection zone

Protection level

Suitable location

TU2-10
TU2-20

LPZ1,LPZ2 zone boundaries of and LPZn
zone

 Class 3

Normally installed in the distribution box of the premises; or installed in the computer information equipment, electronic equipment and control equipment, or the nearest lighting box, socket box.

TU2-40
TU2-60

boundaries of LPZ0B and LPZ1 zone,or LPZ1 and LPZ2 zone

 Class2

Usually installed in the building distribution electric box,metering box;or installed in the computer center,motor housing,building control room,monitoring room, industrial automation,operation room and other places of power distribution box;also can be installed in the general distributionbox of the six floors below building, or the general distribution box of villa

TU2-80
TU2-100

LPZOA,LPZ0B zone boundaries of LPZ1 zone

 Class1

Usually installed in the piercing
lined low voltage main distribution
cabinet

TU2-1

Used in LPZ0A,LPZ0B zone

 Class 1

Usually used in lightning riskhigher equipment system of the first primary surge protection, installed in the general distribution box of distribution box, outdoor distribution box and so on.

Distribution network grounding systemvoltage

Grounding system

TT system

TN-S system

TN-C-Ssystem

IT system

The maximum voltage of the grid

345V/360V

253V/264V

253V/264V

398V/415V

Main technical parameters and performance

Project Name

Parameter

TU2-10

TU2-20

Nominal discharge current

 In(kA)

   5

   10

Maximum discharge current

 Imax(KA)

10

20

Maximum continuous operating voltage

 Uc(V)

 275

320

 385

 275

320

 385

Voltage protection level

 Up(kV)

 1.0

1.3

1.3

 1.3

1.5

1.5

Test classification

   Grade III testing

   Grade III testing

Poles

   2,4,1N

   2,4,1N

Structure type

   D,B type

    D,B type

operation status

 Window indicator

Colorless or green:normal,red: fault

Colorless or green:normal,red: fault

Backup protective
appliances(suggestion)

 Backup fuse

   gl/gG16A

     gl/gG16A

 Backup CB

   C10

   C16

 dimensions

   Refer to drawing no.1,3,4

    Refer to drawing no.1,3,4

 

Project Name

Parameter

TU2-10

TU2-20

Nominal discharge current

 In(kA)

 20

30

Maximum discharge current

 Imax(KA)

40

60

Maximum continuous operating voltage

 Uc(V)

 275

320

 385

420

 275

320

 385

420

Voltage protection level

 Up(kV)

 1.5

1.5

1.8

2.0

 1.8

2.0

2.2

2.2

Test classification

   Grade III testing

   Grade III testing

Poles

   1,2,3,4,1N,3N

 1,2,3,4,1N,3N

Structure type

   D,B,X type

    D,B,X type

operation status

 Window indicator

Colorless or green:normal,red: fault

Colorless or green:normal,red: fault

Backup protective
appliances(suggestion)

 Backup fuse

   gl/gG40A

     gl/gG60A

 Backup CB

   C32

   C50

 dimensions

   Refer to drawing no.1,3,4

    Refer to drawing no.1,3,4


Product detail pictures:

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures

High Quality SPD -  SPD 40KA lightning arrester surge protection device – Hawai detail pictures


Related Product Guide:

Our growth depends on the superior equipment ,exceptional talents and continuously strengthened technology forces for High Quality SPD - SPD 40KA lightning arrester surge protection device – Hawai , The product will supply to all over the world, such as: Czech republic, Bangkok, Comoros, we have all day online sales to make sure the pre-sale and after-sale service in time. With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we are trying our best to be your good partner.
  • The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Penny from Rio de Janeiro - 2018.09.29 17:23
    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Rigoberto Boler from Singapore - 2017.05.02 18:28
    Write your message here and send it to us