HW01-100AP Iot Circuit Breaker

Short Description:

Trip type   40A,63A,100A

Rated current  GB10963.1 GB16917
Standards compliant  ≥6Ka
Short-circuit breaking capacity  When the line is leaking, the circuit breaker 0.1S power-off protection
Short circuit protection  protection
Leakage protection When the line is leaking, the circuit breaker 0.1S power-off protection
Leakage protection Value 30-500Ma can be set
Leakage self-test  According to actual usage, you can set the day, hour and minute
Overvoltage and under-voltage protections  When the line is overvoltage or undervoltage, the circuit breaker will be powered off after 3s (0-99s can be set)  Overvoltage setting value 250-320V, undervoltage setting value: 100-200V
Power on delay When A call comes in, it automatically closes, 0-99s can be set
Power off time delay  When the power grid is suddenly cut off, the circuit breaker is in the open state, O-10s can be set
Setting rated current  0.6~1ln
Overload delay protection 0-99S can be set
Over temperature protection
Due to power 0-120°C can be set, circuit breaker opening time can be set 0-99s
Over powerPower limit When the limited power is reached, the circuit breaker will be powered off after 3s (0-99s can be set)
Timing control  Can be set, the body can be set 5 groups of time
Unbalanced  Both voltage and current can be set as a percentage, and the protection time can be set from 0-99s
Recording  680 Switch event logs can be queried locally

Display Chinese and english menu
Frequency Record various operation times of the circuit breaker to determine whether the circuit breaker is within the effective life
Maintain  It can perform setting self-check, device reset,battery reset, record reset, clock synchronZation, restart device, restore system default, etc.
View  Locally can view voltage, current, leakage current, temperature, active power, reactive power, apparent power, power factor, cumulative power, dailu power consumption (view7-dau records)
Manual and automatic integrated control  It can be controlled by mobile phone app or pc, which can be controlled by buttons, and can also be controlled by push rod (handle):
Cover plate, pull rod Equipped with anti-stealing and repairing anti-misclosure mechanical interlock function
Communication method  RS485 standard configuration, 2G/4G.WIFI, NB, RJ45, etc. Can be selected
Software remote upgrade  Programs can be customized according to actual usage conditions to realize remote updates and upgrades

 


Product Detail

Product Tags

Trip type   40A,63A,100A

Rated current  GB10963.1 GB16917
Standards compliant  ≥6Ka
Short-circuit breaking capacity  When the line is leaking, the circuit breaker 0.1S power-off protection
Short circuit protection  protection
Leakage protection When the line is leaking, the circuit breaker 0.1S power-off protection
Leakage protection Value 30-500Ma can be set
Leakage self-test  According to actual usage, you can set the day, hour and minute
Overvoltage and under-voltage protections  When the line is overvoltage or undervoltage, the circuit breaker will be powered off after 3s (0-99s can be set)  Overvoltage setting value 250-320V, undervoltage setting value: 100-200V
Power on delay When A call comes in, it automatically closes, 0-99s can be set
Power off time delay  When the power grid is suddenly cut off, the circuit breaker is in the open state, O-10s can be set
Setting rated current  0.6~1ln
Overload delay protection 0-99S can be set
Over temperature protection
Due to power 0-120°C can be set, circuit breaker opening time can be set 0-99s
Over powerPower limit When the limited power is reached, the circuit breaker will be powered off after 3s (0-99s can be set)
Timing control  Can be set, the body can be set 5 groups of time
Unbalanced  Both voltage and current can be set as a percentage, and the protection time can be set from 0-99s
Recording  680 Switch event logs can be queried locally

Display Chinese and english menu
Frequency Record various operation times of the circuit breaker to determine whether the circuit breaker is within the effective life
Maintain  It can perform setting self-check, device reset,battery reset, record reset, clock synchronZation, restart device, restore system default, etc.
View  Locally can view voltage, current, leakage current, temperature, active power, reactive power, apparent power, power factor, cumulative power, dailu power consumption (view7-dau records)
Manual and automatic integrated control  It can be controlled by mobile phone app or pc, which can be controlled by buttons, and can also be controlled by push rod (handle):
Cover plate, pull rod Equipped with anti-stealing and repairing anti-misclosure mechanical interlock function
Communication method  RS485 standard configuration, 2G/4G.WIFI, NB, RJ45, etc. Can be selected
Software remote upgrade  Programs can be customized according to actual usage conditions to realize remote updates and upgrades

 


  • Previous:
  • Next:

  • Write your message here and send it to us