HW84-C/HW85-C Ultrasonic Water Meter

Short Description:

Meter and Valve integrated in a compact,totally encapsulated, weatherproof, tamper proof and UV-resistant housing.Stainless steel pipe, more sanitary and more safe.Minimum flow rate is more accurate as our permanent flow rate is much smaller with same dynamic range compared with other players in the market. Smart alarm of flow Sensor error, temperature sensor error,overload,low battery,valve defective.Patented flow measuring method and and smart data error correcting


Product Detail

Product Tags

MODEL Norminal Diameter Permanent Flow Rate Transitional

Flow Rate

Minimum Flow Rate Starting Flow Rate Meter Sensor Connection Size Pipe sensor connection size Meter Length
DN(mm) Q3(m3/h) Q2(m3/h) Q1(m3/h) (L/h) Thread Length Connection

Thread

Connection Length Threa

dLength

Thread Specification (mm)
DN15 15 1.0 0.008 0.005 1.2 12 G3/4B 43 15 R1/2 165
Param eters Diameter Range: DN1              Pressure Class : MAP16                Temperature Range:(°C) 0-30               Pressure Loss Class: △p25

5Protection Class: IP68            Pipe Material : Stainless Steel       Working Temperature : (°C)-20-55       Dynamic Range : 125-400

Ambient Class : Class O           EMC Level : E1                               Installation Mode : H/V                        Flow Section Sensitivity Level : U5/D3