Rated control supply voltage | 12VDC,24VDC |
110VAC,220VAC,380VAC 50/60Hz | |
24V..240V AC/DC 50/60Hz | |
Allowable fluctuation range:±10% | |
Rated insulation voltage | AC380V |
Rated power consumption | AC:≤1.5VA DC≤1W |
Range of time delay | 0.1s..100h(selection through knob) |
Setting accuracy | ≤5% |
Repeatable accuracy | ≤0.2% |
Power-up repetition interval | ≥200ms |
Electrical life | 100000 cycles |
Technical Parameters
Mechanical life | 1000000 cycles |
Conventional heat current | 5A |
Utilisation category | AC-15 |
Contact capacity | AC-15: Ue/le AC240V/1.5A AC380V/0.95A |
Altitude | ≤2000m |
Protection degree | IP20 |
Pollution degree | 3 |
Operation temperature | -5..40℃ |
Permissible relative humidity | ≤50%(40℃) |
Storage temperature | -25…75℃ |