Basic Function
LCD display 6+2(default) , battery for display when power off
Bi-directional total active energy measurement, reverse active energy measure in the total active energy
Anti-tamper function: also measure when connect to earth, bypass, or add resistor in circuit. If phase line and neutral line load is different >12.5%, the meter will measure as the bigger load circuit. The meter can measure when missing neutral line
There is three LED indication: tamper, reverse, impulse LED.
Pulse LED indicates working of meter, Pulse output with optical coupling isolation
Insulated protective-class I, Case protective class IP54 by IEC60529
Technical Data
Rate voltage AC |
110V, 120V, 220V, 230V, 240V (0.8~1.2Un) |
||
Rate current/ frequency |
5(60)A, 10(100)A / 50Hz or 60Hz ± 10% |
||
Connection mode |
Direct type |
Accuracy class |
1% or 0.5% |
Power consumption |
˂1W/10VA |
Start current |
0.004lb |
AC voltage withstand |
4000V/25mA for 60s |
Over current withstand |
30lmax for 0.01s |
IP grade |
IP54 |
Executive standard |
IEC62053-21 IEC62052-11 |
Work temperature |
-30℃~70℃ |
Pulse output |
Passive pulse, 80±5 ms |