MAB relay

Automobile and new energy

70A contact switching capability

Operating temperature up to 125

Group normally open contact form

Dust cover and plastic package are available

Available with transient suppression resistors

Dimensions: 26x 26 x 25mm


Product Detail

Product Tags

MAB

S

1

12

A

1

Y

R

Product

number

Product structure

Number of contact groups

Coil voltage

Contact form

Structural form

Pin form

Coil parallel element

S: plastic type

None: dust cover type

1: 1 group

06: 6VDC

12: 12VDC

24: 24VDC

A: NO

1: optical back fast connection terminal

2: PCB terminal

3: iron back fast connection terminal

4: plastic back fast connection terminal

None: QC pin with lock hole

Y: QC pin without lock hole

None: Without transient suppression resistor

R: shunt resistor

D1: shunt diode(anode connection #86)

D2: shunt diode(anode connection #85)

 

Contact parameters

Performance parameters

Contact form

1A

Insulation resistance

100MΩ (500VDC)

Contact material

Silver alloy

Medium pressure

Between contact and coils: 500VAC 1min

Between open contacts: 500VAC 1min

Contact drop (initial)

Typical 20mV, Maximum 300mV

Action time

10ms

Maximum continuous current

70A (23), 50A (125)

Release time

10ms

Maximum switching voltage

50VDC

Ambient temperature

-40~+125

Electrical life

100000

Vibration

10Hz~500Hz 49m/s2

Mechanical life

1000000

Impact

294m/s2 (30G)

Terminal way

Quick connect type terminal

Package type

Plastic package type, dust cover type

Weight

About: 35g

Mechanical behavior

Shell retention: (pull and compression)200N

Pin holding force: (pull and compression)100N

Pinout resistance to bending force: (all direction) 10N

Coil Spec Sheet

Rated voltage

VDC

Operating voltage

VDC

Release voltage

VDC

Coil resistance

Ω±10%

Coil power

W

Parallel resistance

Ω±10%

Equivalent resistance

Ω±10%

Maximum allowable coil voltage

VDC

20

85

6

4.2

0.6

22.5

1.6

-

-

10.1

7.8

6

4.2

0.6

22.5

1.8

180

20

10.1

7.8

12

8.4

1.2

90

1.6

-

-

20.2

15.7

12

8.4

1.2

90

1.8

680

79.5

20.2

15.7

24

16.8

2.4

360

1.6

-

-

40.5

31.5

24

16.8

2.4

360

1.8

2700

317.6

40.5

31.5

Note: When the contact has no load current and the coil resistance is the minimum value, the maximum continuous working voltage allowed to be applied to the relay coil.

Load parameters

Load voltage

Load type

Contact load current

A

On-off s

Electrical durability (times)

Test ambient temperature

On

Off

14VDC

Resistive

on

2

2

100000

At 23

off

Perceptual

on

2

4

For details, please refer to the environmental

temperature curve of the electrical durability test.

off

Lamp

on

0.5

10

off

27VDC

Resistive

on

2

2

At 23